MODEL: LSC-320
UNIQUE FEATURES
- Ergonomic Design
- Flexible & Space Saving Stability Chamber
- Superior Functionality
- Negligible Maintenance
- High Temperature Accuracy
- Better Temperature Uniformity
- Long-Term stability tests
- The Environmental Chamber provides precise control over temperature, humidity, and other environmental factors to simulate real-world conditions. It is crucial for testing the durability, performance, and reliability of products and materials in various industries.
TECHNICAL DATA
- For conditions as per ICH guidelines (International Conference of Harmonization) 25°C -60% RH/40°C -75% RH/30°C -65% RH/ 25°C-40% RH/40°C -25% RH/30°C-35% RH.
- Temperature Range: 10.0°C to 60.0°C
- Accuracy/Uniformity: ±0.1°C/+1°C
- Humidity Range: 25% to 95% RH
- Accuracy/Uniformity: ±2% RH / ± 3% RH
- Temperature/Humidity display: Digital LED 3.5 digit.
- Control: Microprocessor based PID control Auto tune.
- Resolution: 0.1°C/1% RH
- Temperature sensor: PT-100
- RH sensor: Direct capacitance type
- Heating: 'U' shaped tubular heater in stainless steel.
- Cooling: CFC free Copeland make compressor utilizing R 134A eco friendly refrigerant, with condenser, motor and relay or as per the requirement of customer for higher accuracy.
- Steam injection: Boiler with reservoir made of thick stainless steel, with heater, water inlet control, low water level safeguard
- Air circulation: cooling type fan with impellar/blower and flange type motor.
- Construction: Double wall, outer cabinet mild steel powder coated and inner chamber stainless steel 304 grade, Double door - outer metal body and inner acrylic door.
- Chamber illumination: Fluorescent light with door switch.
- Castor wheels for easy move ability with minimum weights bearing of 50kg.
- Trays: Stainless steel wire mesh heavy duty.
- Electrical: 230V/15A/50 Hz
- Calibration certificate by ERTL - Mumbai with traceability ERTL.
SAFETY FEATURES
- High Temperature safety cut off
- Low water level boiler cut off
- Electrical overload cutoff relay for compressor
- Time delay for compressor switch ON
- Electrical circuit breaker
PRE INSTALLATION MANDATORY REQUIREMENT
- (Guarantee void in case of non compliance)
- a) Distilled water or DM water continuous supply with tap for boiler input of % "BSP at 3 feet height.
- b) Room temperature around machine preferably at 25°C with air conditioning or a well ventilated room with exhaust fan. However, surrounding temperature should not exceed 30°C.
- c) Stabilized input voltage of 230V A.C Amps. Use of servo controlled stabilizer is recommended.
- d) Water Drain line with 1/2" nozzle to be provided at floor level.
OPTIONAL ACCESSORIES
- Micro PLC Based Control & Recording System for Reach in stability testing chamber with in-built Recording, PC Interface with 21 CFR Software, DOT - Matrix Printer Interface.
- R.H. Imported Sensor for 100% RH Readings.
- Standby Refrigeration Systems as per capacity.
- PLC for auto change over for standby refrigeration.
- CFR 21 part 11 compliance software for PLC with Rs. 485 or Ethernet Communication.
- Data Logger for Rs. 485 communication system with PC Connectivity.
- 4, 8 and 12 channel Data Scanner complete with sensor RH and PT-100 Sensor.
- SMS Mobile alert system.
- Door Access Security system.
- Safety Digital Temperature Controller
- Timer
- Recommended Stabilizer.